Humidity Controler

Saturday, August 17, 2013

Flow Totalizer

low Input: Linear Voltage (0-5V DC OR 1-5V DC, Linear Current (4-20mA), Two Wire Transmitter Input (All Linear inputs can be configured with or without Square Root Extraction) OR Frequency Input
Temperature Input: RTD PT-100 OR Thermocouple (K,E,J) – For Temperature Compensation (Compensation possible with TUPC-FC)
Pressure Input: Linear Voltage (0-5V DC OR 1-5V DC, Linear Current (4-20mA) –For Pressure Compensation (Compensation possible with TUPC-FC)
Display: Flow Rate, Accumulated or Total Flow, Pressure & Temperature
Accuracy: 0.2%FS
Output for Batch Control: Relay
Set Point: Set point Range Limit; Dual Set Point Switch; Remote Set point
Alarm: High & Low Alarms for Flow, Temperature and Pressure
Communication: RS485 (Plug-in Module)
Re Transmission O/P: Linear Current or Voltage (SV OR PV)
Power Supply: SMPS100~240VAC/DC‚50Hz OR 24 V DC, Size : 96X96X100mm
Optional :  Flow sensors/Transmitters 48VAC/24VDC supply, control/Alarm output, Dual Display, Jumbo Display, with Flame Proof RTDs , Thermocouples, Transmitters, universal Power supply , Wire Gland, Space mounting, Retransmission output 4-20mA  and  loop powered indicator etc… 

 Application : All Process Indicating systems, Heat treatment Furnace , Oven, Cooling Chamber , molding , packing machine , AC , refrigerator , clean Room environment , online pressure , humidity etc … 