** The unit has an inbuilt time limit for the on time of the actuator fixed at approximately 2.5 minutes. This is to ensure that if the actuator fails to move the panel to the required target angle for more than 2.5 minutes, the unit turns off the actuator load to preserve battery life and indicates “mech failure” for 3 seconds on the LCD display before skipping to the next target angle. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Monday, September 30, 2013
Saturday, August 17, 2013
Temperature Recorder in chennai
Accept input RTD, Thermocouple, Voltage , Current
Process – Temperature , Pressure,
Humidity ,Level
Flow,Co2, Air velocity, Diff pressure
etc …
Optional for with and with out
Display
Also available single pen and
2/3/6/12 point ( Input)
Operating Voltage 110 VAC or 230 VAC
Chart speed
20 mm/ hour and up to 200 mm/ hour optional
Chart Size 120mm or 180 mm , pen and
multi color ribbon
External
power supply for transmitter optional
Cutout
size : 208 X266 mm
Optional
: Sizes, 110VAC supply, Digital Display, single pen and Multi Point recorder, chart speed,
chart size with RTDs, Thermocouples, Enclosure , Transmitter Power supply ,
metal case , wall mounting and control panel
Application : All temperature/
Humidity/Pressure Indicating and
recording systems, Heat treatment Furnace , Oven, Cooling Chamber , molding ,
packing machine , AC , refrigerator , Room environment etc
portable thermometer in chennai
TDPI Series Digital Temperature Indicator Micro-controller based,
micro-power, precision general purpose thermometer designed for used with type
J, K, T, R, S, & RTD – PT100 sensors, Accuracy : 0.1 % of FS
Display: 5 DGT 15 mm high LCD ,Resolution: 0.1oC
Input: J, K, T, R, S, PT100,CJ Compensation: Automatic of 1oC Accuracy
Effect of Lead Wire:
RTD - 1oC for 10% of nominal resistance per lead of 3 wire RTD's
T/C's - 1oC for T/C lead wire resistance of 100 Ohm.
Display: 5 DGT 15 mm high LCD ,Resolution: 0.1oC
Input: J, K, T, R, S, PT100,CJ Compensation: Automatic of 1oC Accuracy
Effect of Lead Wire:
RTD - 1oC for 10% of nominal resistance per lead of 3 wire RTD's
T/C's - 1oC for T/C lead wire resistance of 100 Ohm.
Power supply:6 VDC (1.5 V X 4 No
Alkaline)
Recommended DURACELL type MN1500-LR6
LOW Battery: Provided
Enclosure Size: 80 X 140 x 22 mm approx
Supplied with leather case.
Enclosure Size: 80 X 140 x 22 mm approx
Supplied with leather case.
Optional : with Thermocouple as
per Range , dual / single Input, with Digital power operated Indicator,
Controller , Recorder , Leather bag , IR Thermometer and Calibration
Certificate etc…
Humidity transmitter in chennai
Transmitter
Accept input RTDs,Voltage ,current
Process – Temperature and Humidity
Temperature Range
: 0 to 50 Deg C
Temperature Out put : 0 /4-20mA ( 2 Wire)
Humidity Range
: 0 to 100 % RH
Humidity Out put : 0 /4-20mA ( 2 Wire)
Calibration Zero and Span adjustment
Accuracy
:±2%rh/±0.3k, Power supply : 12-36 VDC
Output
Load at 20 mA , 600 ohms maximum @ 24 VDC
With
Display optional , Range select at
factory
Single/
Dual Input optional , wall mounting
Optional
: 110VAC supply, Dual/Single output,
Single Display, Jumbo Display, with RTDs , Thermocouples, Transmitters,
Enclosure , universal Power supply , metal case , wall mounting, Retransmission
output 4-20mA and loop powered indicator etc…
Application : All Process
Indicating systems, Heat treatment Furnace , Oven, Cooling Chamber , molding ,
packing machine , AC , refrigerator , clean Room environment , online
pressure
, humidity etc …
Flame Proof controller in chennai
Accept input RTD, Thermocouple, Voltage , Current
Process – Temperature , Pressure,
Humidity ,Level
Flow,Co2, Air velocity, Diff pressure
etc …
Resolution Available 0.01/0.1/1
Display Range -999 to 9999 counts
Wall
mounting , Power supply : 230 VAC
CMRI Group
I,IIA&IIB Certified Flame
Proof Enclosure
Retransmission out put 4 -20mA optional
Control Relay output , Optional Dual
Display(PV/SV)
Optional
: 110VAC supply, 20A Relay
,control/Alarm output, Dual Display, Jumbo Display, with Flame Proof RTDs ,
Thermocouples, Transmitters, universal Power supply , Wire Gland, Space
mounting, Retransmission output 4-20mA
and loop powered indicator etc…
Application : All Process
Indicating systems, Heat treatment Furnace , Oven, Cooling Chamber , molding ,
packing machine , AC , refrigerator , clean Room environment , online pressure
, humidity etc …
Temperature Indicator in chennai
Accept input RTD, Thermocouple, Voltage , Current
Process – Temperature , Pressure, Humidity
,Level
Flow,Co2, Air velocity, Diff pressure
etc …
Resolution Available 0.001/0.01/0.1/1
Display Range -999 to 9999 counts
Panel /Wall
mounting , Power supply : 230 VAC
Large display sizes 1”,2”,4”,6”,8”
Manual selection 2/4/6/8/10/ 12 Zones
available
Size
available as per No of Zone and Display size
Optional
: 110VAC supply, control/Alarm
output, Single Display, Jumbo Display, with RTDs , Thermocouples, Transmitters,
Enclosure , universal Power supply , metal case , wall mounting, Retransmission
output 4-20mA and loop powered indicator etc…
Application : Process Indicating systems for institutes,
Industries ,mapping , Heat treatment
Furnace , Oven, Cooling Chamber , molding , packing machine , AC , refrigerator
, clean Room environment , online pressure , humidity PID controller
Input: Universal [All type of
thermocouple and PT100‚ Cu50 (RTD)‚ linear voltage‚ linear current‚ MV‚ 2 wire
transmitter input]
Program: 50 steps
(TUTC-P50); 30 steps (TUTC-P30); event output
Output: Relay‚ SSR‚ Linear voltage‚ linear
current‚ Output range limit Control algorithm: AI PID / AI MPT; heating /
cooling dual output with 2 sets of PID; auto tuning; Set point: Set point range
limit; dual set point switch; remote set point Alarm: High‚ low‚ high deviation
and low deviation, Communication: RS 485‚ RS 232 (Modularized Installable)Re
transmission O/P: Linear current or voltage (SV OR PV), Power supply: SMPS
100~240VAC/DC‚ 50 Hz OR 24 V DC ,Accuracy: 0.2%FS Display resolution: 0.001° C
(Selectable)Size (W x H x D): 48 x 48 x 95 (TUPC4848)‚ 96 x 96 x 100 (TUPC9696)
, Operating ambient: Temp.: 10°C~60°C‚ humidity: <90%RH
Optional : 48VAC/24VDC supply, control/Alarm output,
Dual Display, Jumbo Display, with Flame Proof RTDs , Thermocouples,
Transmitters, universal Power supply , Wire Gland, Space mounting,
Retransmission output 4-20mA and loop powered indicator etc…
Application : All Process Indicating systems, Heat
treatment Furnace , Oven, Cooling Chamber , molding , packing machine , AC ,
refrigerator , clean Room environment , online pressure , humidity etc …
Universal signal Isolator
·
Input (Single or dual): All type of
thermocouple and PT100‚ cu50 (RTD)‚ linear voltage‚ MV‚ linear current
·
Re transmission O/P (Dual): Linear
current (4 20 mA) or voltage (Freely defined)
·
Power supply: SMPS 100~240VAC‚ 50 Hz
·
Re transmission accuracy: 0.3%FS± 1
Digit
·
Display resolution: 0.001° C (Selectable)
·
Size (W x H): 22.5 x 100 (DIN rail)
·
Other features: Input offset
·
Operating ambient: Temp.: 10C~60°C‚
humidity: <90%RH
ultra compact size, DIN
Rail-mounted, Dual channel, Acts as signal isolator, Acts as signal repeater
Optional : 24 VDC supply, with Display, Jumbo Display, with RTDs ,
Thermocouples, Transmitters, Enclosure
and loop powered indicator etc…
Application : All Process
Indicating systems, Heat treatment Furnace , Oven, Cooling Chamber , molding ,
packing machine , AC , refrigerator
,
clean Room environment , online pressure , humidity etc …
Input: Universal [All type of
thermocouple and PT100‚ Cu50 (RTD)‚ linear voltage‚ linear current‚ MV‚ 2 wire
transmitter input]
Program: 50 steps
(TUTC-P50); 30 steps (TUTC-P30); event output
Output: Relay‚ SSR‚ Linear voltage‚ linear
current‚ Output range limit Control algorithm: AI PID / AI MPT; heating /
cooling dual output with 2 sets of PID; auto tuning; Set point: Set point range
limit; dual set point switch; remote set point Alarm: High‚ low‚ high deviation
and low deviation, Communication: RS 485‚ RS 232 (Modularized Installable)Re
transmission O/P: Linear current or voltage (SV OR PV), Power supply: SMPS
100~240VAC/DC‚ 50 Hz OR 24 V DC ,Accuracy: 0.2%FS Display resolution: 0.001° C
(Selectable)Size (W x H x D): 48 x 48 x 95 (TUPC4848)‚ 96 x 96 x 100 (TUPC9696)
, Operating ambient: Temp.: 10°C~60°C‚ humidity: <90%RH
Optional : 48VAC/24VDC supply, control/Alarm output,
Dual Display, Jumbo Display, with Flame Proof RTDs , Thermocouples,
Transmitters, universal Power supply , Wire Gland, Space mounting,
Retransmission output 4-20mA and loop powered indicator etc…
Application : All Process Indicating systems, Heat
treatment Furnace , Oven, Cooling Chamber , molding , packing machine , AC ,
refrigerator , clean Room environment , online pressure , humidity etc …
Direct
Input Accept PH electrode, TDS/Conductivity
cell
TDS
Ranges 0-9999ppm or 0-99.99ppt
PH Range 0.00
to 14.00 PH, Pressure -1 to1000 Bar/PSI
Resolution 0.001/0.01/0.1/1 selectable
Display Range -1999 to 9999
Selectable
100-240 VAC mains operated with 24VDC
Transmitter supply
Offset, Hysteresis, Range selectable,
Dual output
Retransmission out put 4 -20mA optional
Auto/Manual
Temperature compensation
Size
available 96X96mm , wall 192X110mm
Optional
: output 20A relay, Input Type,
customized input with Fixed Range, Dual
output , Transmitters, Relay/SSR, Electrodes , TDS/Conductivity cell, Enclosure
, RT output , metal case , wall mounting and control panel etc…
Application : All Process
Indicating and Controlling systems, Heat treatment Furnace , Oven, Cooling
Chamber , molding , packing machine , AC , refrigerator , Room environment etc
…
Flow Totalizer
low Input: Linear Voltage (0-5V DC OR
1-5V DC, Linear Current (4-20mA), Two Wire Transmitter Input (All Linear inputs
can be configured with or without Square Root Extraction) OR Frequency Input
Temperature Input: RTD PT-100 OR Thermocouple (K,E,J) – For Temperature Compensation (Compensation possible with TUPC-FC)
Pressure Input: Linear Voltage (0-5V DC OR 1-5V DC, Linear Current (4-20mA) –For Pressure Compensation (Compensation possible with TUPC-FC)
Display: Flow Rate, Accumulated or Total Flow, Pressure & Temperature
Accuracy: 0.2%FS
Output for Batch Control: Relay
Set Point: Set point Range Limit; Dual Set Point Switch; Remote Set point
Alarm: High & Low Alarms for Flow, Temperature and Pressure
Communication: RS485 (Plug-in Module)
Re Transmission O/P: Linear Current or Voltage (SV OR PV)
Power Supply: SMPS100~240VAC/DC‚50Hz OR 24 V DC, Size : 96X96X100mm
Temperature Input: RTD PT-100 OR Thermocouple (K,E,J) – For Temperature Compensation (Compensation possible with TUPC-FC)
Pressure Input: Linear Voltage (0-5V DC OR 1-5V DC, Linear Current (4-20mA) –For Pressure Compensation (Compensation possible with TUPC-FC)
Display: Flow Rate, Accumulated or Total Flow, Pressure & Temperature
Accuracy: 0.2%FS
Output for Batch Control: Relay
Set Point: Set point Range Limit; Dual Set Point Switch; Remote Set point
Alarm: High & Low Alarms for Flow, Temperature and Pressure
Communication: RS485 (Plug-in Module)
Re Transmission O/P: Linear Current or Voltage (SV OR PV)
Power Supply: SMPS100~240VAC/DC‚50Hz OR 24 V DC, Size : 96X96X100mm
Optional : Flow sensors/Transmitters 48VAC/24VDC supply,
control/Alarm output, Dual Display, Jumbo Display, with Flame Proof RTDs ,
Thermocouples, Transmitters, universal Power supply , Wire Gland, Space
mounting, Retransmission output 4-20mA
and loop powered indicator
etc…
Application : All Process Indicating systems, Heat
treatment Furnace , Oven, Cooling Chamber , molding , packing machine , AC ,
refrigerator , clean Room environment , online pressure , humidity etc …
Friday, July 5, 2013
Master Pressure Gauge
The Digital Master Pressure Gauge Accept Unit
kg/cm2,Bar,PSI,KPA,mmHg, mmH2O,inchHg,inchH2O ,
The Gauge suitable for Pressure Gauge Calibration.
Available Range -1 Bar ( -760mmHg) to 700 Bar as per Customer
requirement .
calibration Password protected
The Gauge is an Ultra Low Power microprocessor Controlled, accurate and
versatile Digital Pressure Instrument
,Thermal drift operational amplifier
ensures good stability. Calibration Point can be set very
accurately. TDPG are available in many
models. When Indicate” LO” sensor is
open condition . The instrument is housed In a compact Aluminum Anodize case
. 1000 Hours Battery Life
7.5 VDC Battery Operated Recommended DURACELL type MN1500-LR6.
Optional : Display Range fixed or adjustable , Unit
selectable or Fixed, with calibration comparator , master calibration
certificate ( NABL Lab), password protection, available with SS316, process connection
¼ “ BSP M or customized etc…
Application : All Testing ,
measuring and calibration lab, chemical & Oil Industries , Oven, Cooling
Chamber , molding , packing machine , AC , refrigerator , Room environment etc
…
tempsen
We undertaken Tempsen devices is a
leading organization that has established in 1987 itself in the manufacture of
wide range of Industrial Process control Instruments Temperature, Humidity,
Pressure,CO2,Moisture in Oil , Level, Air Velocity and Air Flow Indicator,
Controller, Recorder, Data Logger, Scanner, Paper less Recorder, Thermocouples,
RTD sensors, SSR and Jumbo Indicators , Counter, Timer, Transmitters &
sensors etc…
Saturday, April 6, 2013
Humidity Temperature Logger with Enclosure manufacture in chennai
Temperature Humidity Data Logger in chennai
Contact us
TEMPSEN DEVICES
An ISO 9001:2008 Certified Company
Plot No : 2&3, 4th Street, Balaji Nagar, Mettukuppam
Thoraipakkam, Chennai-600 097, Telefax : +91-44-24581758
Mobile : +91-9841291758, Customer Care : +91-9841201758
Email:tempsen@yahoo.com,solution@tempsendevices.net
Website : www.tempsendevices.net
Subscribe to: